The business case for sustainable design keeps getting stronger. Consider these takeaways from theWorld Green Building Trends 2016 Smart Market Report:

That second bulletthe operational savings over the lifespan of a buildinggets most of the attention when it comes to sustainable design. Yet what impact does sustainable design have on owners with a finite construction budget or developers who wont own the building after construction? Historically, this group has been told that a high-performing building will only cost themmoremoney to constructdollars that may not be available in project financing. But it is no longer true that sustainable buildings have to be more expensive.

We have delivered many deep green projects that came in below cost or at similar price points to what those same buildings would have cost without sustainable design elements. We did this by focusing on three tactics for improving sustainability: leveraging integrated design, employing energy modeling and programming for efficiencies.

Integrated design helped the LEED-Platinum DC Consolidated Forensic Lab come in 17 percent under budget.

With integrated design, all stakeholdersarchitect, mechanical engineer, contractor, preconstruction services consultant, cost estimator, building owner and operator, and other consultantscollaborate early and often to understand how building systems link to one another and then use that knowledge to find efficiencies and tradeoffs. While this approach requires more planning on the front end, it often leads to free or passive solutions that reduce system loads and building costs. Integrated design might reveal, for example, how a slight modification to a buildings orientation can reduce solar heat gain and increase natural daylighting, resulting in less expensive HVAC and lighting components.

Our work on theDC Consolidated Forensic Labprovides a real-world example of how integrated design can lead to first-cost savings. The LEED Platinum building in Washington, D.C., came in 17 percent under budget with much of the savings due to its sustainability. For instance, collaboration with the projects mechanical engineer, Vanderweil, resulted in outfitting the building with an active chilled beam system, heat shift chiller, enthalpy wheels and glycol energy recovery loops that reduced the mechanical load of the building and the number of chillers that would have been required with a traditional HVAC system. Because chilled beams are a hydronic system that do not require nearly as much plenum space as traditional air ducts, we were also able to reduce the floor-to-floor height of the building, which led to construction and material savings.

As part of the integrated design process, we knew that the building operator desired sustainable features to reduce long-term energy use and costs. This information allowed us to incorporate a dynamic glass louverwall along the buildings south facade. The glass louvers (featuring a 50 percent ceramic frit pattern) serve as a solar shield, automatically adjusting, opening and closing depending on sun angle, wind and barometric pressure. Unlike a true double-skin facade, the louversset three feet off the curtainwallallow the airspace between the exterior wall and sunscreen to vent without impacting air pressurization requirements in the interior lab space while at the same time mitigating solar heat gain and glare along the south of the building.

Energy modeling revealed how a passive cooling system could cut expenses at NOAAs Pacific headquarters.

Energy modelingsoftware simulation that provides detailed analysis of a buildings energy usehelps us understand long-term and short-term consumption costs. This crucial component of integrated design often leads to additional savings and helps justify the costs of sustainability features that might not be immediately apparent.

Energy and computational fluid dynamics (CFD) modeling of theNational Oceanic and Atmospheric Administration Daniel K. Inouye Regional Centerin Pearl Harbor, Hawaii, which was honored with anAIA COTE 2017 Top Ten Green Project award, showed how a passive cooling system would provide substantial operational and first-cost savings compared to other HVAC options. The novel cooling system we used on the building pumps cold seawater from a 1,300-foot-deep well to the buildings chillers where heat is rejected into the seawater, eliminating the need for traditional cooling towers. The seawater then flows into a series of chilled coils. The system takes advantage of the trade winds to drop chilled air passing over the coils into the building without using mechanical fans.

Deep seawater is pumped to the rooftop of NOAAs Inouye Center. Trade winds then send water-cooled air into the building.

Savings from the cooling system allowed the design team to outfit the LEED-Gold project with additional sustainable design features, such as increased daylighting. Designers used small-scale mockups to test the size and spacing of daylight openings to provide even daylight levels across office work areas. As construction proceeded, full-scale mockups fine-tuned the teams initial daylight studies, ensuring that interior workplaces took advantage of the maximum amount of natural light while also blocking direct sun exposure. Once in operation, the NOAA Inouye Regional Center achieved 33 percent annual energy savings in addition to its first-cost neutral sustainable design.

Energy modeling isnt just for building owners who care about sustainability or LEED certification. Energy modeling can often find savings that far exceed the costs of setting up and running the energy simulation software.

In Washington, D.C., we designed a multi-building commercial office project (Constitution Square Buildings 1, 2, 3) that achieved LEED Platinum status without additional building costs. For the final phase of that project, Constitution Square Building 4, the developer secured a full-building tenant and hoped to leverage building performance to position the structure for higher resale value without increasing first costs. Energy modeling on that project, however, revealed that by reducing the buildings window-to-wall ratio from 56 percent to 51 percent and improving the window glazing, the design team could reduce the number of chillers that service the building. In this case, the energy model ROI was dramatican investment of $24,000 to perform iterative modeling at all design and Value Engineering stages netted approximately $500,000 in first-cost reduction, bringing the mechanical system back into budget while maintaining 35 percent energy savings. The developer has since sold the building (still under construction) at a price that reflects its high-performance design.

A review of how employees would use NASA Building 20 allowed HOK designers to reduce its size by 11 percent.

Taking a detailed look at how many people will occupy a building and how they will use the space can help teams design for efficiencies.

HOKs work onNASA Johnson Space Center Building 20in Houston shows how using this planning strategy can both reduce costs and improve a buildings sustainability. In the RFP for the project, NASA specified it wanted a LEED-Silver building of approximately 93,000 square feet. In reviewing how the buildings 520 employees would use the space, our team was able to reduce the overall building size by 11 percent while still meeting the requirements of the agencys occupants.

In reducing the square footage of NASA Building 20, the design team was able to add other sustainability features, such as a sloped ceiling that allows daylight to penetrate deeper into the interior space.

Savings from the compact design opened the budget for additional sustainability featuresincluding exterior sunshading devices, advanced lighting controls, a building section optimized for daylighting and an underfloor air distribution (UFAD) systemthat ultimately earned the project 57 percent energy savings and LEED-Platinum status without going over budget.

The previous examples demonstrate how a holistic design approach can enable clients to build higher-performing projects for a lower cost than initially expected. But even if sustainable design does not lead to first-cost savings or neutral building costs compared to more conventional designs, there still are reasons to consider sustainable strategies.

Our internal research, for example, has found that if energy modeling doesnt pay for itself during design and construction, it almost always will within the first few months of a buildings operation. And, as theDepartment of Energy has reported, thats true regardless of building typebe it an office building, hotel, hospital or research lab.

The bottom line is sustainable design is more achievable than ever and no longer has to be more expensive to deliver. The key is getting all parties to invest the time and resources early onand throughout the processto fully explore the options and understand how they can improve a project.

Anica Landreneau, Assoc. AIA, LEED AP, works out of HOKs Washington, D.C., office and is the firms director of sustainable design. In addition, she oversees HOKs efforts to achieve acarbon-neutral design portfolio by 2030.

Read the original post:
Green buildings don't have to cost more - Building Design + Construction (press release) (registration) (blog)

Related Posts
May 3, 2017 at 1:41 am by Mr HomeBuilder
Category: Office Building Construction